Abstract

Due to the differences in the line resistance of each distributed generation unit, conventional sag control does not allow for precise distribution of power, which also reduces the problem of system reactive power accuracy. To address this problem, this paper analyzes the power equalization and distribution conditions. A method for adaptive adjustment of virtual resistance by system output power feedback is submitted. Reducing the variance among the original line resistances aims to solve the problem of power not being evenly divided and improve the equalization of reactive power. By building a Simulink parallel simulation model of the inverter, it is verified that the power feedback-based fetching and the improved droop control is effective.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call