Abstract

We report operating temperatures and heating coefficients measured in a multilayer black phosphorus device as a function of injected electrical power. By combining micro-Raman spectroscopy and electrical transport measurements, we have observed a linear temperature increase up to 600 K at a power dissipation rate of 0.896 K μm(3)/mW. By further increasing the bias voltage, we determined the threshold power and temperature for electrical breakdown and analyzed the fracture in the black phosphorus layer that caused the device failure by means of scanning electron microscopy and atomic force microscopy. The results will benefit the research and development of electronics and optoelectronics based on novel two-dimensional materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.