Abstract This paper presents results of our study of the performance of a Potassium DPAL operating in pulsed mode with pump pulses from 0.05 to 5 ms long at different pump powers and alkali cell temperatures. The experiments showed the DPAL output power degradation in time with a characteristic time in the range from 0.5 ms to 4.5 ms. We attribute the power degradation to heating of the vapor. The recorded spectrum of the side fluorescence indicates that multi-photon excitation, energy pooling collisions and ionization are also present.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.