Abstract

An active method for double-frequency power ripple decoupling in single-phase inverters is presented in this paper, exhibiting the main advantage of not using additional power semiconductors besides the H-bridge. The proposed method requires only two capacitors placed between the midpoint and one end of each inverter leg. An original control solution of the inverter ensures the power ripple transfer toward the two decoupling capacitors without affecting the inverter output voltage. The simple design makes the proposed solution easy to adapt for single-phase inverters in H-bridge configuration. This paper focuses on the autonomous operation mode of the inverter, detailing its operating principle and the control analysis. The system performances, including the impact of the decoupling circuit on the inverter efficiency, are assessed by means of experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call