The power balance measurements in a 1 kW argon helicon plasma discharge are demonstrated. The quantitative wall heat flux measurements using nonintrusive infrared imaging of the glass tube surface, along with data from bolometric probes and calibrated photodiodes to measure heat flux from the rest of the plasma, are shown. For the cylindrical discharge, with radius much less than the axial length, approximately 15% of 1 kW input power is lost in the transmission lines and matching network, 54% is lost through radial particle transport to the walls, 16% is lost through radiation, and 8% is lost through ion impact in the vicinity of the antenna. Wall erosion of the confining glass tube occurs due to sputter etching by ions accelerated in the electrostatic fields produced by the antenna. Wall etch rate measurements are used to quantify particle fluxes to the wall, which are in rough agreement with particle fluxes calculated from thermal flux.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.