Abstract

The simple potentiometric method proposed for the indirect determination of 1–10 mg of gold(III) is based on reduction to the metal with excess of cobalt(II) in the presence of 1,10-phenanthroline or 2,2'-bipyridine at pH 3 and 50°C, and titration of the unused cobalt(II) complex with iron(III) chloride solution. Many metal ions can be tolerated; Ag(I) and Pd(II) are eliminated by precipitation with sodium chloride and 1,10-phenanthroline or 2,2'-bipyridine, respectively, but Hg(II), Fe(III) and Pt(IV) interfere. The method is applied to the determination of gold in alloys.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.