Abstract

Two procedures are proposed for the potentiometric determination of Ag(I), Pd(II) and Au(III) in binary mixtures, by titration with potassium iodide solution, and use of a commercial iodide electrode as sensor. In the first procedure, two aliquots of the mixture are titrated, at pH 2.0 ± 0.2 and 9.0 ± 0.2, adjusted with dilute sulphuric acid and ammonia solution. At pH 2.0, the titrant reacts with both metals, whereas at pH 9.0, Ag(I) is the only reactant. The second procedure utilizes titration of two aliquots of the mixture in the presence and absence of a selective masking agent. The methods have been applied to the determination of these metals in some jewellery alloys.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.