Abstract

Abstract Methods are described for the complexometric determination of calcium and magnesium in seawater, using an amalgamated silver electrode for end-point detection. In the presence of a small amount of mercury(II)-chelonate, the amalgamated silver electrode serves as a pM indicator during the complexometric titration, the Hg complex being stronger than Ca, Mg and Sr complexes. Calcium is determined by titration with EGTA, calcium+magnesium+strontium by titration with EDTA and magnesium is obtained by difference. Average values of 0.02120 (standard deviation 0.00004) for Ca:Cl‰ and 0.06671 (standard deviation 0.00014) for Mg:Cl‰ were obtained for samples from tropical North Atlantic Ocean.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.