Abstract

Pre-denitrification in biofilters is limited by the amount of easily degradable organic substrate, resulting in relatively high requirements for external carbon. The combination of pre-DN, N and post-DN filters is much more advisable for most municipal wastewaters, because the recycle rate can be reduced and external carbon can be saved. For minimum use of external carbon, 100-150% recycle rate should not be exceeded. Then, approximately 50-60% of the total NO3-N can be depleted in the pre-DN stage. On average, 10 g total (t) COD/g NO3-N were required in the pre-DN stage for denitrification in the pilot and full-scale plant and 0.4-0.5 kg NO3-N/(m(3)DN d) can be reached without external carbon. As only 40-70% of the COD load is eliminated in the pre-DN, the remaining COD load is removed in the nitrification stage. 1 kg COD/(m(3) d) suppresses nitrification rates by approximately 0.1 kg NH4-N/(m(3) d). For nitrification rates, > 0.5 kg NH4N/(m(3) d) at 12 degrees C not more than 2 kg COD/(m(3) d) may be eliminated in the nitrification.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.