Abstract

A novel municipal wastewater treatment system, consisting of a combination of an upflow anaerobic sludge blanket (UASB) and down-flow hanging sponge (DHS) posttreatment unit, was continuously evaluated for more than three years with raw sewage as an influent. The system was installed at a sewage treatment site and operated at 25±3°C . This paper reports on the results of a long term monitoring of the system. The whole experimental period was divided into three distinct phases with different operating conditions. Organic pollutants were only partially removed in anaerobic UASB pretreatment unit. The remaining organics as well as nitrogenous compounds were almost completely removed by the DHS posttreatment unit. In all phases the system demonstrated removal efficiency consistently over 95% for unfiltered biochemical oxygen demand (BOD), 80% for unfiltered-chemical oxygen demand and 70% for suspended solids. The system produced an excellent effluent quality with only 4–9 mg∕L of residual unfiltered BOD. Diss...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.