Abstract
AbstractMonitoring well sand packs are theoretically capable of retarding metal ions and organic contaminants. If this retardation does indeed occur it may have a significant effect on the purging requirements of newly installed monitoring wells. Calculations based on mass balance and retardation concepts demonstrate that if common guidelines for well purging are followed, contaminants may not be detected or may be detected in lower concentrations than are actually present in the ground water. This problem is greatest in relatively shallow wells installed in low to moderate permeability materials. In most cases, the effect of solute retardation in the sand pack can be avoided simply by additional purging prior to the first sampling of the monitoring well. Common purging guidelines can then be applied to subsequent samplings. The methodology outlined in this paper can be used to calculate the purging requirements of existing monitoring wells or it may be applied to alternative monitoring well designs to test which will require the smallest volume of purged water.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.