Abstract

The performance of a pilot‐scale upflow anaerobic filter (UFAF) treating a dairy wastewater was studied for a period of 3 months. Results showed that the UFAF system achieved over 85% chemical oxygen demand (COD) and 90% biological oxygen demand (BOD5) removal efficiencies at an organic loading rate (OLR) of 6 kg COD/m3.d with a hydraulic retention time (HRT) of 20 hours. Percent methane in the biogas produced in the UFAF was found to be in a range of 75%‐85% with the corresponding methane yield of 0.32–0.34 m3 CH4/kg COD removed. The system produced approximately 770 liters CH4/day. This would maintain all energy requirements of the feed and recirculation pumps and mixing. Approximately 35% of the energy requirement for maintaining the desired temperature of the pilot‐scale anaerobic filter column would also be recovered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.