Abstract
The seismic hazard of vulnerable regions warrants the investigation of new technologies, such as base level isolation by lead rubber bearing (LRB) devices, that can help to mitigate structural damage on seismic prone buildings. The behavior adopting such technologies can be dynamically observed in simulated environments and thus serves as a valuable metric for their feasibility. LRB base isolators were incorporated into the design of 16 model buildings to better understand how they affected a building’s seismic response while also providing information on the structural parameters. A total of 12 different types of bearing systems were tested in base isolated (BI) buildings against conventional fixed-base (FB) isolated buildings. The system of each model high-rise building was represented by the finite element package. Static as well as dynamic analysis were conducted using response spectrum analysis (RSA) based on the seismic excitation to determine the influence of the model type in the aseismic design and the alteration in superstructure behavior. The study reveals that the LRB isolators can potentially diminish respective story accelerations, story inertia, and base shear. Use of LRB isolators in BI buildings resulted in a 10–20% reduction in base shear compared to FB buildings. A notable lateral shift of superstructure is offered by LRB-induced flexibility. The reduction of story acceleration for response spectrum varies 30% on lower stories up to 70% on upper stories. The LRB systems with higher characteristic strength and relatively less isolation periods shows better productivity to minimize displacements in the bearing face for dropping structural shift. However, the LRB with comparatively lower characteristic strength and high isolation periods shows the most efficiency in controlling base shear, offering least story accelerations and consenting lower story inertia forces.
Highlights
During sudden earthquakes, extreme ground excitation creates a huge ground acceleration which may cause severe structural damage to multi-story buildings
Use of lead rubber bearing (LRB) isolators in base isolated (BI) buildings resulted in a 10–20% reduction in base shear compared to FB
A notable lateral shift of superstructure is offered by LRB-induced flexibility
Summary
Extreme ground excitation creates a huge ground acceleration which may cause severe structural damage to multi-story buildings. To avoid such structural damage, the strength capacity of the buildings needs to be increased. Designing conventional fixed-base (FB) buildings to withstand such level of forces will lead to exorbitant construction costs. The earthquake itself cannot be controlled, its effect on the structure can be controlled by minimizing the effect of the motion of the foundation on the structure above using bearing isolation. The isolation system provides additional flexibility and energy dissipation capability by installing between the foundation and superstructure [1,2,3,4]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.