Abstract

Pharmaceutically active compounds (PhACs) widely present in urban wastewater effluents pose a threat to ecosystems in the receiving aquatic environment. In this work, efficiency of granular activated carbon (GAC) - based catalytic processes, namely catalytic wet peroxide oxidation (CWPO), peroxymonosulfate oxidation (PMS/GAC) and peroxydisulfate oxidation (PDS/GAC) at ambient temperature and pressure were studied for removal of 22 PhACs (ng L−1 level) that were present in secondary effluents of real urban wastewater. Concentrations of PhACs were measured using Ultra Performance Liquid Chromatography – Triple Quadrupole Mass Spectrometry (UPLC-QqQ-MS/MS). Catalytic experiments were conducted in discontinuous mode using up-flow fixed bed reactors with granular activated carbon (GAC) as a catalyst. The catalyst was characterized by means of N2 adsorption-desorption isotherm, mercury intrusion porosimetry (MIP), elemental analysis, X-ray fluorescence spectroscopy (WDXRF), X-ray diffraction (XRD), thermal gravimetry and differential temperature analyses coupled mass spectrometry (TGA-DTA-MS). Results indicate that the highest efficiency in terms of TOC removal was achieved during CWPO performed at optimal operational conditions (stoichiometric dose of H2O2; TOC removal ~ 82%) followed by PMS/GAC (initial PMS concentration 100 mg L−1; TOC removal ~73.7%) and PDS/GAC (initial PDS concentration 100 mg L−1; TOC removal ~ 67.9%) after 5 min of contact time. Full consumption of oxidants was observed in all cases for CWPO and PDS/GAC at contact times of 2.5 min, while for PMS/GAC it was 1.5 min. In general, for 18 out of 22 target PhACs, very high removal efficiencies (> 92%) were achieved in all tested processes (including adsorption) performed at optimal operational conditions during 5 min of contact time. However, moderate (40 – 70%) and poor (< 40%) removal efficiencies were achieved for salicylic acid, ofloxacin, norfloxacin and ciprofloxacin, which can be possibly attributed to insufficient contact time. Despite high efficiency of all studied processes for PhACs elimination from urban wastewater effluent, CWPO seems to be more promising for continuous operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.