Abstract

To perform a dosimetric comparison between intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy in patients with locally advanced (stage III and IV) tumours of the supraglottic region treated with conservative surgery and post-operative radiotherapy. An in-silico plan using a 3D conformal shrinking field technique was retrospectively produced for 20 patients and compared with actually delivered IMRT plans. Eighteen structures (arytenoids, constrictor muscles, base of tongue, floor of mouth, pharyngeal axis, oral cavity, submandibular glands and muscles of the swallowing functional units [SFU]) were considered. IMRT allowed a reduction of maximum and mean doses to 9 and 14 structures, respectively (p < .05). IMRT achieved a reduction of unnecessary dose to the remnant larynx and the majority of surrounding SFUs. Further prospective analyses and correlations with functional clinical outcomes are required to confirm these dosimetric findings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.