Abstract

Laparoscopic primary or incisional abdominal hernia repair with intraperitoneal mesh placement is a well-accepted and safe technique. Evidence for complications however remains inconclusive, and little is known about the occurrence of postoperative ileus secondary to postoperative intra-abdominal adhesions with different types of IPOM meshes used. Therefore, we retrospectively compared the occurrence of postoperative ileus between two of the different meshes used in our center. Three hundred seventy-five patients who underwent ventral hernia repair with intraperitoneal mesh placement, either with a DynaMesh®-IPOM (FEG Textiltechnik mbH, Aachen, Nordrhein-Westfalen, Germany) or a Parietex™ Composite mesh (Medtronic, Minneapolis, MN, USA), at the Heilig-Hart Hospital in Lier (Antwerp, Belgium) between 2012 and 2017 were retrospectively compared with regard to the occurrence of postoperative ileus until 6weeks postoperatively. Baseline demographics and clinical data up to 6weeks postoperatively of the patients in the two mesh groups are provided. The DynaMesh®-IPOM mesh group was associated with a significantly higher incidence of postoperative ileus compared with the Parietex™ Composite mesh group with a cutoff limit at postoperative day 1 (n= 17, 6.8% vs. n= 0, 0.0%; P= 0.003) and postoperative day 4 (n= 13, 5.2% vs. n = 0, 0.0%, P= 0.006), even with a mesh surface area of ≤ 300cm2 and when both meshes were fixated with the same method of fixation (Securestrap™) with a cutoff limit for postoperative ileus at postoperative day 1 (n= 4, 7.7% vs. n= 0, 0.0%; P= 0.013) and postoperative day 4 (n= 3, 5.8% vs. n = 0, 0.0%, P= 0.040). Of the 17 patients with a postoperative ileus, 9 (52.9%) had a suspicion of adhesive small bowel obstruction on CT scan (P= 0.033) with definitive confirmation of small bowel adhesions with the DynaMesh®-IPOM mesh at laparoscopy in 2 patients. Our results confirm current literature available regarding postoperative ileus secondary to postoperative intra-abdominal adhesions with the DynaMesh®-IPOM mesh. However, further research with well-designed, multicenter randomized controlled studies to evaluate the use and related complications of these meshes is needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.