Abstract

A radioisotope scanning and clearance procedure has been developed for the postoperative assessment of third ventriculostomy patients. The patency of third ventriculostomy sites can be verified by this procedure, and the bulk flow clearance of CSF can be quantitated. 4 postoperstive third ventriculostomy patients have been evaluated by this procedure to date. In each case the third ventriculostomy site was shown to be patent. The bulk flow clearance of CSF ranged from 170 to 342 cm3/24 h. Comparison of these figures with estimates of CSF production suggests that the majority of CSF reabsorption in these patients occurs through the arachnoid villi.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.