Abstract

The deuterium inventory at Joint European Torus in co-deposits and bulk material in inner, outer and upper wall components of the vacuum vessel exposed in 2007–2009 has been determined using nuclear reaction analysis and secondary ion mass spectrometry and optical microscopy. Approximately 1.8 g of the deuterium is retained in these areas, which corresponds to ∼0.07% of the retained deuterium.