Abstract

Studies evaluating the change in serum phosphate post hemodialysis (HD) demonstrate an initial decline during dialysis but a rebound post dialysis. However, previous studies were done on usual diet and phosphate binders, with limited number of blood draws, confounding conclusions. We determined serum phosphate reduction, rebound, and equilibrium over 48 h in HD patients consuming a controlled, low phosphorus diet without binders. Serum phosphate (mg/dL) was analyzed before and after a HD treatment and frequently during the ensuing 48 h intradialytic period in the clinical research unit. Thirteen subjects were enrolled and had been off phosphate binders for 10 days and consumed a standardized low phosphate (900 mg/day) diet for 3 weeks prior to the assessments. Linear regression was used to determine relationships between the pre-HD serum phosphate, decline post-HD (post-HD drop); and a 48 h area under curve (AUC) using the trapezoidal method as a measure of overall phosphate levels from the end of dialysis to 48 h post dialysis. Repeated Measures ANOVA with Dunnett's posthoc test was used to determine rebound. Five of 13 subjects returned to >90% of their pre-HD serum phosphate within the first 24 h post-HD, and serum phosphate was 94 ± 0.11% (range 63%-113%) by 48 h after the completion of HD. The 48 h AUC of serum phosphate during the interdialytic period was correlated with both pre dialysis phosphorus (r=0.85; p=0.0002) and the pre-post drop in serum phosphate during dialysis (r=0.69; p=0.0085). In contrast, the net ultrafiltration was not related to the 48 h AUC of serum phosphorus (r=0.20; p=0.51). In hemodialysis patients on standard low phosphorus diet and no phosphate binders, the interdialytic serum phosphorus level, assessed as AUC, is determined by the pre dialysis phosphorus and net-change in serum phosphorus during the dialysis treatment, but not the ultrafiltration volume [Correction added on 25 January, after first online publication: In the last sentence of the Abstract, the word "potassium" has been replaced with "phosphorus" to improve accuracy.].

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.