Detailed measurements of post-arc current in a vacuum were made. This investigation was particularly characterized by conducting post-arc current measurements following high arc currents (36 kA rms maximum). Postarc current increases with main arc current, and shows a sharp increase when the main arc current reaches certain value. The magnitude of post-arc current for each contact material differed; the descending order is Cu-Bi > Cu > Cu-W > Ag-W. Shield current was also measured to clarify the characteristics of the ion current. Cu-Bi > Cu > Cu-W > Ag-W was the descending order of measured shield current. The characteristics of post-arc current are explained by referring to those results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.