Abstract
The considered test was a break on the upper plenum with different modes of emergency core cooling. The reference case was the non-availability of emergency cooling. Injecting the emergency coolant into the cold leg, no increasing of rod cladding temperatures was observed, but natural circulation instabilities occurred. Injecting the cooling into the hot leg, the cooling situation was getting worse. Due to the injected cold emergency coolant, the fluid density in the discharge volume was enhanced and the break mass flow increased. The observed events in the test were reproduced by the code with good agreement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.