AbstractWhen reinforcing bars are post‐installed in holes drilled in cured concrete, adhesive mortars are used to create a bond between concrete and bars. Appropriate adhesives can develop higher bond strengths than standard ribbed bars cast into concrete. A detailed design concept for the anchorage length of reinforcing bars has been developed by taking into account splitting/spalling of the concrete and pullout. Pullout and splitting tests on reinforcing bars set in concrete were carried out with different adhesive mortars and with varying concrete strengths and concrete covers. When higher bond strengths than those recommended for cast‐in reinforcement are taken into account, it is important to check deformations and crack widths at the serviceability limit state (SLS) separately. For this reason, structural tests on slabs and corbels were carried out. Moreover, pullout tests on post‐installed reinforcing bars were performed in order to measure displacements at service load level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.