Abstract

A series of fire experiments was performed to study the gas temperature development and charring behaviour of timber construction compartments. The measured gas temperatures were 300-500 C lower than predicted by the parametric temperature-time curves of Eurocode 1 for unprotected and insufficiently protected timber structures. For structures protected with a double layer of gypsum plasterboard, the agreement was better. In all cases, however, the prediction was on the safe side. One protective layer of gypsum plasterboard delayed the onset of charring for 20 min. Using two layers, the delay time was doubled. Reduced charring rates for long exposure times were observed, resulting from the increasingly protective effect of the char layer withtime.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.