Abstract

Fire represents one of the significant hazards encountered by civil infrastructures, and thus providing appropriate fire safety measures is a major requirement in a building design for ensuring the safety of the occupants. Minimizing fire-induced damage and collapse of structural systems are the primary objectives in the design of concrete structures. An experimental investigation has been carried out to examine the mechanical properties such as compressive, tensile and flexural strengths of concrete exposed to elevated temperature following standard fire curve as per ISO 834. Capacity-based standards have been formulated to predict the residual strength of various grades of concrete exposed to various duration of heating. Stress strain behaviour, elastic modulus, weight loss, spalling and thermal crack pattern of specimens were also investigated. Water–cement ratio and porosity of concrete were found to be the critical factors for strength loss of concrete. A relationship is established between weight loss and strength loss of concrete. Higher grades of concrete were found to have more weight and strength loss than those of lower grades.