Abstract

The post-fire bond behaviour between the steel tube and core concrete in elliptical concrete filled steel tubes (ECFST) is studied in this paper. A total of 15 post-fire push-out test specimens, including 9 elliptical, 3 circular and 3 square CFSTs, were designed and tested. The testing parameters included: (a) target temperatures (Ttar = 20 °C, 600 °C and 800 °C); (b) high temperature duration time (td = 30 min, 60 min, 180 min and 300 min); (c) length of long axis of elliptical section (2a = 200 mm and 300 mm); (d) section type (elliptical, circular and square). The test results indicated that the target temperature and high temperature duration time affected the post-fire bond strength of ECFSTs significantly, and the post-fire bond strength of ECFSTs could be increased with the increasing values of the two parameters. Based on the test data, a two-linear stage bond stress versus slip constitutive model considering the influence of both the temperature and fire-exposed surface area was proposed and verified to capture the post-fire bond behaviour in ECFSTs, which could be used in the refined bond behaviour numerical analysis of ECFSTs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.