This paper assesses the post-demagnetization performance of interior permanent magnet (IPM) ac machines by employing the more accurate recoil line approach based on a 2-D transient finite-element analysis (FEA). The method predicts continuous demagnetization of each magnet element undergoing partial demagnetization and evaluates the machine behavior after an event of short-circuit faults across its terminals. Along with the short-circuit faults, a failure in a drive controller or a position sensor, which may lead to a reverse voltage across the machine terminals that can eventually be more fatal and can cause significant reduction in the performance due to high levels of demagnetization, is analyzed as the worst case scenario. The FE predicted post-demagnetization performance is validated by experimental measurements in which a six-phase IPM machine designed for electric vehicle traction is allowed to lose its synchronization with the inverter when forced to operate on a torque–speed envelope, which is way beyond the drive voltage setting.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.