Abstract

Abstract. The calibration of the Moderate-resolution Imaging Spectroradiometer (MODIS) 6.8 μm water vapor (WV) channel was assessed by comparing Terra/MODIS measurements with the WV channel brightness temperatures equivalent to Infrared Atmospheric Sounding Interferometer (IASI) measurements for June 2007 and December 2007. IASI spectral information was transferred to the Japanese Multifunctional Transport Satellite (MTSAT)-1R WV channel and then to the MODIS WV channel. Results indicate that the MODIS WV channel is biased low by 2–3 K, possibly caused by the shift of the spectral response function by about +11 cm−1. This finding is particularly important because the bias of −3 K can cause about +30% relative errors in the retrieval of upper tropospheric humidity (UTH) over the tropics. In other words, the current MODIS measurements may result in higher UTH values, showing relative errors up to +30%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.