Abstract

Recent upgrade of the neutral beam system has resulted in considerable improvement of the plasma parameters in the gas dynamic trap experiment. With injection of 5 ms, 20 keV, 4.5 MW neutral beams the electron temperature approaching 250 eV was obtained. At the same time maximal plasma beta attained about 60%. Further progress in plasma temperature and pressure could only be possible with considerable increase of the magnetic field in the central solenoid and re-optimization of its profile to improve stability of high-beta plasma, as well as with extension of the neutral beam pulse. Possible steps in this direction are considered in this paper.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have