Abstract

The CS (Central Solenoid) insert coil is configured as a single layer winding inside the 2 m bore of the CSMC (CS Model Coil), with a long uniform field over the center up to 13 T. Tcs (ramped temperature) and Ics (ramped current) measurements have been performed. The coil showed a premature voltage development in the Tcs test. After 10 000 current cycles of the insert, there was a further drop of 0.4 K in the measured current sharing temperature, associated with individual quenches during the cycling. In this paper, the possible causes for the premature voltage gradient are assessed. The process includes application of the single strand data to assess the expected performance of the insert coil and consideration of the impact of variations of strand current and field across the cable cross-section, using a new analysis program for nonuniform current diffusion in long multistrand cables.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.