Abstract

The surface tension of water is suspected to show a substantial increase at low temperatures, which is considered to be one of the many anomalies of water. The second inflection point (SIP) anomaly, originally claimed to be at around -8 °C, was experimentally refuted down to -25 °C by Hrubý et al. (J. Phys. Chem. Lett. 2014, 5, 425-428). Recent molecular simulations predict the SIP anomaly near or even below the homogeneous freezing limit of around -38 °C. To contribute to an ongoing discussion about the SIP anomaly, new experiments focused on extreme levels of supercooling were carried out in this study. Unique experimental data down to -31.4 °C were collected using two measuring techniques based on the capillary rise method. A significant deviation from the extrapolated IAPWS formulation R1-76(2014) for surface tension of ordinary water was detected below -20 °C. Contrary to previous data, new experiments provide room for an anomaly in the course of surface tension in the deeply supercooled region.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.