Abstract

We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H¯) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H¯+), which has been cooled to a low temperature, and observing the subsequent H¯ annihilation following free fall. To produce one H¯+ ion, about 1010 positrons, efficiently converted into positronium (Ps), together with about 107 antiprotons (p¯), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) × 109 positrons in 1100 s.