Abstract

BackgroundPost-extubation-atelectasis (PEA) is a common problem after the removal of an endotracheal tube in neonates which increases the rate of extubation failure. Different techniques have been introduced for the prevention of PEA. One technique is the removal of the endotracheal tube by negative or positive gradients of pressure. No RCT has yet been done to compare the use of these two methods in neonates. So this study aimed to compare the role of positive and negative pressure during extubation of neonates on the prevention of PEA. Materials and methodsWe enrolled 100 newborns in this RCT that required at least 24 h of mechanical ventilation. The endotracheal tube in one group was removed by a T-Piece resuscitator at a PEEP level of 5 CmH2o while in another group extubation was done applying suction pressure of 100 mmHg by random selection. Prevalence of PEA in CXRs after extubation was compared between the two groups. ResultsThe prevalence of PEA in the extubation of the positive pressure group (24%) was significantly lower than that of the negative pressure group (46%) (p = 0.024). Extubation failure was found to be lower in the positive pressure group (6% versus 20% P = 0.037). No significant difference was observed between the two groups in the prevalence of apnea, pneumothorax, and death at 3 days after extubation. ConclusionThe use of positive pressure during removal of the endotracheal tube in newborn infants reduced the rate of PEA compared with the negative pressure so extubation by a positive pressure is recommended in neonates.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call