Abstract

Intraoperative complications, especially unexpected bleeding, are of great concern in the safety of thoracoscopic surgery. We investigated the hemostatic efficacy and safety of positive intrapleural pressure (PIP) with carbon dioxide insufflation by assessing the amount of blood loss in a pulmonary arterial hemorrhage model. An ex vivo experimental model of saline flow into a swine vessel was created in a container simulating a chest cavity. From the results, in vivo experiments (swine model) were conducted to compare the pulmonary arterial bleeding volume while applying PIP. In the ex vivo experiment, regardless of the incision type, the outflow volumes did not significantly differ at flow pressures of 20, 30, and 40 mmHg. At each flow pressure, the outflow volumes at 10, 15, and 20 mmHg of positive pressure in the container were significantly smaller than those of the control (p = 0.027, p = 0.002, and p = 0.005, respectively). Similarly, the in vivo experiments showed that bleeding decreased as intrapleural pressure increased (slope = -0.22, F = 55.13, p <0.0001). It may be possible to temporarily suppress pulmonary arterial bleeding by increasing the intrapleural pressure to 10 to 20 mmHg using carbon dioxide insufflation. This method may be an adjunctive hemostatic maneuver for intraoperative bleeding.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call