Abstract

A numerical/experimental study on the monitoring of the skin buckling phenomenon in stiffened composite panels by embedding optical fibres is presented in this paper. A numerical procedure has been introduced able to provide the most efficient embedded optical fibre path (with minimum length) fulfilling the grating sensors locations and directions requirements whilst satisfying specific embedding/integrity constraints for the optical fibre. The developed numerical procedure has been applied to a stiffened composite panel under compression load. The best location and direction of the grating sensors and the optimal optical fibre path for the monitoring of the skin buckling phenomenon have been found by performing respectively non-linear FEM analyses and optimization analyses. The procedure has been validated by means of an experimental testing activity on a stiffened panel instrumented with embedded optical fibres and back-to-back strain gauges which have been positioned according to the numerically estimated grating sensors locations and directions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.