Abstract

This paper proposes a new scaleless position estimation method. From the industrial perspective, the Hall sensor has several advantages: tiny size, light weight, extremely low cost, and insensitivity to environmental contamination and external disturbance. Compared to the square wave Hall sensor, the linear Hall sensor provides more detailed information along the position. However, for combining more than two linear Hall sensors, the sensor offset, the difference in scale, and the unwanted phase shift between them and the harmonics would decrease the validity and reliability of sensor measurement. The fast Fourier transform and the fixed point iteration method are applied to compensate for those issues without any low-pass filter or additional signal conditioning. The effectiveness of the proposed scheme is verified through a prototype permanent magnet linear synchronous motor system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.