Abstract

The position control of an energy efficient electrohydraulic actuation system is a decisive characteristic of its performance. In position control applications, a servo valve and/or variable displacement pump are vital to control the position of the linear actuator. In this open-loop control experimental work, the position of a linear actuator having a stroke length of 0.2 m is controlled by a swashplate-controlled electro hydrostatic actuation system. LabVIEW is used to create the control algorithm, and the National Instrument compact-RIO controller is used to control the voltage supply. The National Instruments controller processes sinusoidal and square demand signals at frequencies of 1/16, 1/12, 1/8, and 1/4 Hz. Open-loop control performance is predominantly dependent on the appropriate tuning of the voltage supply. Control performance is evaluated using the parameters integrated absolute error, integrated square error, integrated time absolute error, and integrated time square error. In comparison to square demand, it has been found that sinusoidal demand offers better position control accuracy, and square demand also offers appropriate control accuracy only at lower frequencies (1/16 Hz).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call