Abstract

Background:Handheld ultrasound (HHUS) devices have increasingly found their way into clinical practice due to several advantages (e.g. portability, significantly lower purchase cost). However, there is no evidence to date on the accuracy and performance of HHUS in patients with inflammatory arthritis (IA).Objectives:To assess accuracy and performance of a new HHUS machine in comparison to a conventional cart-based sonographic machine in patients with IA.Methods:Consecutive IA patients of our outpatient clinic with at least one tender and swollen joint in the 66/68 joint count were enrolled. US was performed on clinically affected joints with corresponding tendons/entheses using a cart-based sonographic device (“Samsung HS40”) and a HHUS device (“Butterfly iQ”) in standard scan positions. One blinded reader scored all images for the presence of following pathologic findings: erosions, bony enlargement, synovial hyperthrophy, joint effusion, bursitis, tenosynovitis and enthesitis. In addition, synovitis was graded (B Mode and power Doppler (PD)) by the 4-level EULAR-OMERACT scale [1]. To avoid bias by the blinded reader, who otherwise would have been tempted to identify pathological findings for each examined joint, we also included 67 joints of two healthy volunteers into the evaluation. We calculated the overall concordance and the concordance by type of joint and type of pathological finding between the two devices (percentage of observation pairs in which the same rating was given by both devices). The Cohen’s kappa coefficient (κ) with 95% bootstrap confidence intervals was used to assess the agreement between the two US devices. We also measured the time required for the US examination of one joint with both devices.Results:32 patients (20 rheumatoid arthritis, 10 psoriatic arthritis, 1 gouty arthritis, 1 systemic lupus erythematosus) were included in this study. Mean age of patients was 58.2±13.7 years, 63% were females. In total 186 joints were examined. The overall raw concordance in B-mode between the two devices was 97 %, with an overall κappa for agreement of 0.90, 95% CI (0.89, 0.94). No significant differences were found in relation to type of joint or pathological finding examined. The PD-mode of the HHUS device did not detect any PD-signal, whereas the cart-based device detected a PD-signal in 61 joints (33%). The portable device did not offer any time saving compared to the cart-based device (mean time in seconds per examined region: 47 seconds for the HHUS device versus 46.3 seconds for the cart-based device).Conclusion:The HHUS device “Butterfly iQ” has been shown to be accurate in the assessment of structural joint damage and inflammation in patients with IA, but only in B-mode. Significant improvements are still needed to reliable demonstrate blood flow detection by PD mode.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call