AbstractThis paper describes the technique of improving the sensitivity of bulk micromachined silicon pressure sensors with judicious use of porous silicon (PS) and porous polysilicon (PPS). Since PS has a much lower Young's modulus than Si, pressure sensors with Si/PS composite membranes show higher sensitivity. The sensitivity also increases as the porosity of the PS layer increases. Further improvement in sensitivity can be achieved by replacing the conventional polysilicon piezoresistors with porous polysilicon ones. Though the composite membranes exhibit higher sensitivity, they suffer from higher offset voltage due to the stress developed by the formation of porous silicon. Pressure sensors with silicon membrane and porous polysilicon piezoresistors yield modest improvement in sensitivity without increase in offset voltage. A combination of porous polysilicon piezoresistors and composite membranes with microporous silicon gave the highest sensitivity value as well as the highest offset. (© 2009 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.