Abstract

A porcelain faucet handle failed after years of use in a residential rental property. Determining the cause of failure was hampered by the fact that the failed handle was no longer available. The analysis included mechanical testing of exemplar faucet handles to measure the reasonable forces that could be applied by hand and the forces necessary to cause failure. Interface geometry between the porcelain handle and the interior metal nut was a factor. Finite Element Analysis facilitated the study. Results showed that if the faucet handle had sustained damage during a gasket repair, then the failure could be accounted for.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.