Abstract
Abstract Boiling tests on the equimolar pentane/tetradecene mixture at 1 aim over plain, HIGHFLUX, TURBO-B, GEWA-TX, and LOW-FIN tubing are described. Heat fluxes ranged from 5 to 60 kW/m2. A large reduction in heat transfer coefficient compared to boiling pure pentane was observed. Surfaces with tunnel structures performed only as well as the LOW-FIN surface. In all but the HIGHFLUX tube case, an unstable film of tetradecene-rich liquid built up and periodically broke away from the surface. This behavior increases the difficulty of developing successful nucleate boiling predictions for wide-boiling mixtures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.