Abstract

Polyolefins are important and broadly used materials. Their molecular microstructures have direct impact on macroscopic properties and dictate end-use applications. 13C NMR is a powerful analytical technique used to characterize polyolefin microstructures, such as long-chain branching (LCB), but it suffers from low sensitivity. Although the 13C sensitivity of polyolefin samples can be increased by about 5.5 times with a cryoprobe, when compared with a conventional broadband observe (BBO) probe, further sensitivity enhancement is in high demand for studying increasingly complex polyolefin microstructures. Toward this goal, distortionless enhancement by polarization transfer (DEPT) and refocused insensitive nuclei enhanced by polarization transfer (RINEPT) are explored. The use of hard, regular, and new short adiabatic 180° 13C pulses in DEPT and RINEPT is investigated. It is found that RINEPTs perform better than DEPTs and a sensitivity enhancement of 3.1 can be achieved with RINEPTs. The results of RINEPTs are further analyzed with statistics software JMP and recommendations for optimal usage of RINEPTs are suggested. An example of analyzing saturated chain ends in an ethylene-octene copolymer sample with a hard 180° 13C RINEPT pulse is demonstrated. It is shown that the experimental time can be further reduced in half because of faster proton relaxation, where the total experimental time is about 580 times shorter when compared to using a conventional method and a 10 mm BBO probe. A naturally abundant nitrogen-containing polyolefin is analyzed using 1H-15N HMBC and, to our knowledge, is the first 1H-15N HMBC presented in the field of polyolefin characterization. The relative amount of similar nitrogen-containing structures is quantified by two-dimensional integration of 1H-15N HMBC. Two pragmatic technical challenges related to using high-sensitivity NMR cryoprobes are also addressed: (1) A new 1H decoupling sequence Bi_Waltz_65_256pl is proposed to address decoupling artifacts in 13C{1H} NMR spectra which contain a strong 13C signal with a high signal-to-noise ratio (S/N). (2) A simple pulse sequence that affords zero-slope spectral baselines and quantitative results is presented to address acoustic ringing that is often associated with high-sensitivity cryoprobe use.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call