Abstract
We demonstrate microrings assembled with polyacrylamide (PAM) microfibers for high-sensitivity relative humidity (RH) sensing. When exposed to moisture, the PAM microfiber absorbs water molecules and inflates monotonically with the increasing humidity, resulting in evident spectral shifts of the resonance peaks of the microring. By measuring the spectral shifts, the microring shows sensitivity as high as 490 pm/%RH and a response time of about 120 ms, within a dynamic range from 5% to 71% RH.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.