The objective of this work was to construct the polyaluminium chloride (PACl) diagram of coagulation for secondary effluent from a textile industry in order to determine the best coagulant dose and coagulation pH. PACl doses vary between 200 and 450 mg/L with pH values from 4.5 to 8.0. In addition, it was evaluated the effect of applying a copolymer of acrylamide and sodium-acrylate as a flocculation aid and the addition of a decolourant, composed by dicyandiamide, to increase the colour removal efficiency, at the best coagulant dose and pH obtained. Apparent colour removal of 70% was reached in the pH range and coagulant dose predicted for the enhanced coagulation process: high coagulant doses, between 200 and 450 mg/L; and low coagulation pH, between 4.5 and 5.0. The application of the copolymer and the decolourant resulted in an apparent colour removal between 10 and 30% less than the efficiency obtained with PACl application. These results indicate the need for further studies to optimise the application of these combined products with the PACl and improve the colour removal from textile mill effluent.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Environmental Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.