Abstract

Certain reagents utilized in the formation of polyacrylamide gels are shown to interfere in the Lowry assay for protein. Acrylamide (3–30%) and potassium ferrocyanide (0.0015–0.0105%) produced a linear response in color formation. Both compounds are capable of reducing the phenol reagent in the absence of copper and the interference can be compensated for by employing the appropriate blank. An extract of polymerized and electrophoresed gels also interferes in the Lowry assay, however, this increased color formation cannot be corrected by using a gel extract blank. Under the conditions studied, filtration, centrifugation, and dialysis did not sufficiently remove the acrylamide fines responsible for the interference.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.