Abstract

A multichannel far‐infrared (FIR) polarimeter has been installed in RFX, a Reversed Field Pinch (RFP) plasma experiment, to measure the poloidal magnetic field profile. The polarimeter uses a CH3OH FIR laser operating at λ=118.8 μm. Faraday rotation measurements on five of six parallel diagnostic chords are used in preliminary investigations of poloidal field profiles. The experimental results are generally found in good agreement with the μ&p model predictions. The choice of the profile of μ = μ0j·B/B2 is discussed. For the reconstruction of the magnetic field profiles a numerical filamentary current equilibrium code is described, where polarimetric data are included as constraints. An alternative method based on the best‐fit of a three‐parameter μ profile to the polarimetric data is also reported. Both methods provide reliable reconstructions of the plasma magnetic field and the results indicate the existence in RFX of hollow μ profiles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.