Abstract

Precise and accurate procedures have been developed for the polarographic determination of temazepam in soft gelatin capsules. The capsule contents can be determined either by direct-current or by differential-pulse polarography. In order to cover the possibility of temazepam having diffused into the capsule shell a whole capsule assay has been developed based on directcurrent polarography: the differential pulse signal is considerably suppressed by the gelatin present in the shell. For capsules that have undergone storage tests at high temperatures leading to denaturisation, an enzyme dissolution step is included. The procedures are not subject to interference from known degradation products, and can therefore be used for stability determinations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.