Abstract
Hypernumerical aperture and polarized illumination are the key technologies of resolution enhancement of lithography. When the numerical aperture reaches 0.85 and above, especially in the immersion lithography, polarization effect must be taken into consideration. The performance of the projection lens needs to be characterized by rigorous polarization aberration. The vector polarization imaging system that is suitable for hypernumerical aperture is established, and the distortion effects introduced by polarization aberration are analyzed. Orientation Zernike polynomials-based method and Pauli–Zernike polynomials-based method are adopted to parameterize the polarization aberration represented by Jones pupil. Critical dimension error, placement error, and normal int. log slope index are introduced as the index to value imaging distortion. The proposed method and analysis conclusion would provide meaningful guidance for projection lens design of lithographic tools.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.