Abstract

Transthoracic point-of-care ultrasonography of the lungs has become a standard technique in critical care medicine for the evaluation of patients with respiratory signs or symptoms but has not been well studied in pregnancy. To compare lung ultrasound patterns in third-trimester gravidas with and without preeclampsia and assess interobserver agreement between 3 obstetrical providers and a physician expert in critical care lung ultrasound. This is a prospective observational study of 262 women with singleton pregnancies between 32 0/7 and 41 6/7 weeks' gestation. Lung ultrasound examinations were performed and interpreted by a team of obstetrical care providers and then interpreted by an expert in point-of-care lung ultrasound. The number of B-lines in each of the 4 lung fields, indicating the accumulation of fluid in the interstitial space and the alveoli, was evaluated. The primary outcome was a positive study for pulmonary interstitial edema, defined as an ultrasound study with 3 or more B-lines in 2 or more bilateral lung fields. The secondary outcome was a lung ultrasound study with 1 or 2 B-lines in 1 or more lung fields or 3 B-lines in 1 lung field. Interobserver agreement in lung ultrasound interpretation between obstetrical care providers and an expert in critical care point-of-care ultrasonography of the lung was assessed. Among healthy gravidas, no subject had a lung ultrasound examination positive for pulmonary interstitial edema. Notably, 2 patients with preeclampsia had positive lung ultrasound studies, and both had respiratory symptoms or signs of pulmonary edema. One or 2 B-lines or 3 B-lines in 1 lung field were identified in 11.4% of healthy gravidas and 18.6% of patients with preeclampsia. There was no difference in lung ultrasound patterns between healthy gravidas and those with preeclampsia. The obstetrical care providers and the lung ultrasound expert had a high proportion of agreement regarding the interpretation of negative lung ultrasound examinations. The 2 patients with clinical signs of pulmonary edema were judged to have positive studies by both the obstetrical team and the expert; however, the obstetrical team classified more studies as positive. Lung ultrasound patterns in women with preeclampsia without respiratory symptoms or clinical signs of pulmonary edema are similar to the lung ultrasound patterns of healthy gravidas. Point-of-care lung ultrasound can be used to evaluate third-trimester gravidas with preeclampsia and respiratory complaints or signs concerning for pulmonary edema. Formal training is important before the widespread adoption of point-of-care lung ultrasound by obstetrical healthcare providers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call