Abstract

Abstract Background The number of new heart failure (HF) diagnoses in hospitals constantly increases. The associated clinical signs lead to a delay in treatment. Reliable and rapid diagnostic assistance is needed at earlier stages and can be an added value to accelerate the process. Kinocardiography (KCG), based on Seismocardiography (SCG), allows the computation of non-invasive cardiac kinetic energy that is used to characterize the cardiac function and could detect HF among patients at risk. Purpose In a multi-centric study, test the performance of smartphone-based KCG recording in diagnosing HF in the emergency department. Methods Adult patients who presented with dyspnea in the emergency department (ED) were recruited. Clinical charactristics were recorded, including demographics, symptoms, medication use, and diagnostic studies. Additionally, a blood sample was collected for NT-proBNP measurement, and a 180-second KCG acquisition was acquired with a smartphone. The patient is placed supine on the back, and the smartphone is placed on his chest to acquire the precordial vibrations due to the heartbeats. From these vibrations, cardiac kinetic energy (CKE) metrics are derived, including diastolic gradient kinetic energy (ΔiKdiastolic). The final HF diagnosis was assessed from the medical record at discharge from the ED. The primary outcome is the performance of an AI based on CKE metrics at classifying HF, measured using metrics including the area under the receiver operating characteristic curve (AUROC), negative predictive value (NPV), and specificity, with two-sided 95% CIs. Results 295 patients were recruited; among these, 106 patients were diagnosed with HF (78 [69;83] years, 26.9 [23.2;29.3] kg/m2, 42% male, 4933.0 [3299;8055] pg/ml, 67 HFpEF, 10 HFmrEF, 29 HFrEF) and 189 without HF (64 [55;74] years, 28.1 [25.5;31.4] kg/m2, 51% male, 297.0 [90;813] pg/ml). ΔiKdiastolic was significantly lower in patients with HF (0.35 [0.08;0.70] vs. 0.06 [-0.04;0.32] %, p<0.005). The AI approach resulted in an AUROC of 0.82 (0.80–0.89), sensitivity of 82.5% (72·7–90·2), and NPV of 79.3% (77·5–82·6). Conclusion This study shows that an AI system applied to SCG acquired during a 3-minutes examination with a smartphone can detect HF among patients presenting dyspnea. These findings highlight the potential for non-invasive, workflow-adapted, point-of-care, aid-to-diagnosis for earlier diagnosis and prognostically beneficial treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.