Hollow fiber supported liquid membrane microextraction, a relatively new sample preparation technique, has attracted much interest in the field of environmental analysis. In the current study, a novel method based on hollow-fiber liquid-phase microextraction and flame atomic absorption spectrometry (FAAS) for the measurement of copper ion in aqueous samples is described. Hollow-fiber liquid-phase microextraction conditions such as the type of extraction solvent, pH, the stirring rate, and the amounts of chelating agents, sample volume, and the extraction time were investigated. Under the optimized conditions, the linear range was found to be 0.01–15 μg ml−1 for copper ion, and the limit of detection to be 0.004 μg ml−1. Tap water and surface water samples collected from Mashhad, Iran and Dorongar river; Khorasan, Iran, respectively, were successfully analyzed using the proposed method. The recoveries from the spiked water samples were 72.4% and 105%, respectively; and the relative standard deviation (RSD) at the 2 μg ml−1 level was 6%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.